Problem:

Eyeglass configuration replication Job fails with error “AEC_FORBIDDEN…..”.

 

Possible Cause:

Isilon provisioned in Eyeglass with user who does not have minimum required privileges.

 

Troubleshooting Steps:

  1. Cross reference the permissions of the Isilon OneFS user that is used in Eyeglass provisioning with Minimum Required Privileges documented here: support.superna.net.
  2. If the OneFS user does not have the required privileges, update the user privileges in OneFS.  The next Eyeglass configuration replication job will be based on these updated privileges.
  3. If the OneFS user has the minimum required privileges, double check the OneFS user privileges from the Isilon command line to ensure that they are set as required.